Supplying Caterpillar CG170-20 New 2000kW Caterpillar CG170-20 Natural Gas gensets OR Natural gas genset MWM TCG2020V20 50Hz 2000 kW Cummins brand diesel generators All the details that you may need for being certain about your correct MWM diesel generator are as follow: Natural gas Genset MWM TCG2020V20 50Hz 2000 kW 10,5 kV (Same engine as a caterpillar with CG170-20 Cat model) Description Genset Base engine TCG 2020 V20 50Hz Standard alternator n = 1,500 / min Base genset 50Hz, 2MV, Marelli MJH 630 LA4 10500V Exhaust manifold with Exhaust waste gate, manifold 90° vertical Standard conservation (24 months) Exhaust turbocharger Base frame without oil tank, 230/400 V pre-lubrication Combustion air filter without preheating TCG 2020 Suctions System Spare parts for commissioning MWM Base system ТЕМ Operating terminal (BRT) Intelligent selection unit, basis system (IAEBS) Connection parts for 2 ТЕМ cabinets without option "failure indication system" (IAEST) ТЕМ control cabinet, packaging, cables genset test without customer participation Standard documentation (2 copies) incl. preparation Main technical data: Power KW 2000 KW Power Output 1983 KW RPM1500 Fuel Natural Gas Generator Model Alternator: Marelli MJH 630 LA4 Volts 10500 Hz 50 Year of Manufacturing 2018 Total Running Hours 0 Equipment in its original packaging. Attached original Scope of Supply and original technical specifications Natural gas genset MWM TCG2020V20 50Hz 2000 kW 10,5 kV (Same engine as CG170-20 Cat model) Description Genset Base engine TCG 2020 V20 50Hz Standard alternator n = 1,500 / min Base genset 50Hz, 2MV, Marelli MJH 630 LA4 10500V Cooling type (HE, KC, or RC), 50Hz/1500RPM or 60 Hz/1800 RPM Natural gas Genset MWM TCG2020V20 50Hz 2000 kW 10,5 kV (Same engine as CG170-20 Cat model) Power Output 1983 KW RPM1500 Fuel Natural Gas Generator Model Alternator: Marelli MJH 630 LA4 Volts 10500 Hz We have Cummins lean-burn gas engines QSV91G in stock with zero run hours due to a canceled project 1450kW – 6.3kV – 50Hz lean burn  (flare gas but suitable to run NG)Gen-set comes with muffler – cooler – controller PCC3.3 – gas street Specification sheet Natural gas generator set QSV91 series engine 1540 kW – 2000 kW Description Cummins lean burn gas generator sets are fully integrated power generation systems utilizing state-of-the-art technology that results in optimum performance and efficient use of fuel for standby and continuous duty, CHP, and peaking applications. Features Cummins® heavy-duty engine – Rugged 4-cycle lean burn gas combustion engine utilizing full authority electronic engine management and monitoring. Exhaust emissions- Learning burn technology provides exhaust emissions levels as low as 250 mg/Nm3 (0 5 g/hp hr) NOx . Fuel Flexibility – Ability to run on natural gas as well as alternative gaseous fuels with lower BTU properties and varying Methane Numbers (MN) . Permanent magnet generator (PMG) – Offers enhanced motor starting and fault clearing short circuit capability. Alternator – Several alternator sizes offer selectable voltage and temperature rise with low reactance 2/3 pitch windings; low waveform distortion with non-linear loads, fault clearing short-circuit capability, class F or H insulation (see Alternator Data Sheet for details), bearing and stator RTDs and anti-condensation heater. Mechanically strengthened for use on utility paralleling with the unreliable grid. Control system – The Power Command 3.3 generator set control is standard equipment and provides total Genset system integration including full paralleling capability in grid or load share mode, precise frequency and voltage regulation, alarm and status message display, AmpSentry™ protection, output metering, auto-shutdown at fault detection and a user interface panel installed onto the Genset. Optional grid code compliant control systems and remote operator panels are also available on select models. Cooling system – The generator set is equipped with the capability of interfacing with a remote radiator or heat exchanger Warranty and service – Backed by a comprehensive warranty and worldwide distributor A network that can provide all levels of service from replacement parts to performance guarantee programs. Base load (continuous) power (COP)definition Applicable for supplying power continuously to a constant load up to the full output rating for unlimited hours. No sustained overload capability is available for this rating. Consult authorized distributor for rating. (Equivalent to Continuous Power in accordance with ISO 8528, ISO 3046, AS2789, DIN 6271, and BS 5514). NATURAL GAS GENSET – MWM TCG2020V20 50Hz 2000 kW, * For natural gas applications (NOx <= 500 mg / Nm3 *) * Power data at 50 Hz , 2.000 kWe * Warranty: 24 months or 16.000 running hours (what happens before), but no longer than 30 months after manufactureItem description Gen Set MWM TCG 2020 V20 50Hz NG with integrated oil tank and TEM Power cabinet 400V, 4000A + Connecting cable about 10 m Modul control cabinet, with installed TEMP EVO Connection cables, Cable shelves, Generator connection Power cable about 10 m + Nickel-plated brass seals Another equipment: Oil refill tank with pump Plate heat exchanger M10-BFM Alfa Laval (2018) Gas collector with pressure regulator and filter Cooler Circulation pump (cooler) with control valves Flue gas condenser Circulation pump (heat) Chimney (Stainless steel) with damper Chimney metal construction 15 m Air intake (galvanized sheet metal) Air outlet (galvanized sheet metal) Special agents commissionCaterpillar CG170-20 tedarikinde profesyoneliz Yeni 2000kW Caterpillar CG170-20 Doğal Gaz jeneratörleri VEYA Doğalgazlı jeneratör MWM TCG2020V20 50Hz 2000 kW


Leave a Reply

Your email address will not be published. Required fields are marked *